Connecting an iib to a ceb – CTI Products IIB Console Interface User Manual
Page 24
![background image](/manuals/334820/24/background.png)
IIB Hardware Reference
Connecting an IIB to a CEB
CTI Products, Inc.
68-10844-115
19
9.
Connecting an IIB to a CEB
The following example shows how you would connect an IIB to Motorola’s CEB
(Central Electronics Bank) in a comparator display system. Figure 11 shows what
this system looks like.
CA-80029-100
CA-80029-100
COMPARATOR
OUT
IN
T
IN
OUT
MODULE
MCN
1
COMPARATOR
16 I/O
CEB
RX1-4
RX5-8
IIB
P/S
A
16 I/O
B
T
I/O
Figure 11 - IIB / CEB Connection Example
The IIB connects to the CEB through two 16 I/O cards (cards A and B) Each 16
I/O card can handle only 4 receivers. The CEB must be configured so that the 16
I/O cards operate as comparator display boards. Table 7 shows the cross
connections needed between the IIB and the 16 I/O cards. Once these
connections are made, you need to install jumper JU6 through JU33 on each 16
I/O card.