IIB Hardware Reference

Connecting an IIB to a CEB

CTI Products, Inc.

68-10844-115

19

9.

Connecting an IIB to a CEB

The following example shows how you would connect an IIB to Motorola’s CEB
(Central Electronics Bank) in a comparator display system. Figure 11 shows what
this system looks like.

CA-80029-100

CA-80029-100

COMPARATOR

OUT

IN

T

IN

OUT

MODULE

MCN

1

COMPARATOR

16 I/O

CEB

RX1-4

RX5-8

IIB

P/S

A

16 I/O

B

T

I/O

Figure 11 - IIB / CEB Connection Example

The IIB connects to the CEB through two 16 I/O cards (cards A and B) Each 16
I/O card can handle only 4 receivers. The CEB must be configured so that the 16
I/O cards operate as comparator display boards. Table 7 shows the cross
connections needed between the IIB and the 16 I/O cards. Once these
connections are made, you need to install jumper JU6 through JU33 on each 16
I/O card.