Option Switches

CTI Products, Inc.

68-10854-135

8

4.

Option Switches & Jumpers

Three sets of option switches are provided for module configuration. The module
must be power cycled or reset after these switches are set so that the options will
take effect. Table 2 describes the option switches and shows the factory defaults.

SWITCH

DESCRIPTION

DEFAULT

GROUP

unit address setting (00-FE)

refer to the MCN System Manual

00

MODULE

unit address setting (0-F)

refer to the MCN System Manual

0

OPTION
position 1

comparator selector 1 (see Table 3)

DOWN

position 2

comparator selector 2 (see Table 3)

DOWN

position 3

transmitter monitoring enable

DOWN

position 4

force-vote timeout

DOWN

Table 2 - CIB Option Switches

4.1

Group & Module Switches

The Group and Module selector switches are used to set the node address during
module installation. Refer to the Monitor and Control Network System Manual
for details about setting these switches.

4.2

Comparator Selector Switches

The comparator selector switches set the type of comparator the CIB is operating
with. Settings for these switches are shown in Table 3.

Comparator

Selector 1

SW 1

Comparator

Selector 2

SW 2

Comparator

Type

Selected

DOWN

DOWN

Spectra TAC

DOWN

UP

Digitac

UP

DOWN

TAC, G.E.,
JPS SNV-12,
Doug Hall 4RV/2

UP

UP

other

Table 3 - Comparator Selector Switch Settings

If your specific comparator is not listed in Table 3, set both comparator selection
switches to the UP position for “other”. With this setting, the CIB will monitor
the VOTE, RECEIVE, DISABLE, and FAIL inputs from the comparator and pass
the status information to the display interface module. Also, the display interface
module can control the VOTE and DISABLE outputs of the CIB.