Remote operation – CTI Products CHIB CommandSTAR Lite Host Interface Module User Manual
Page 18
CHIB Hardware Reference
Remote Operation
CTI Products, Inc.
68-11662-100
14
10. Remote
Operation
Because of the protocol between the CommandSTAR Lite console and the CHIB
module, modem connection between the CHIB and the console is not supported.
The CHIB must always be connected locally to the console (within the appropriate
RS-485 or RS-232 distance limits).
If display and control of a remote comparator is required, this can be done with
standard MCN EXB Network Extender Modules. These modules are available in
the following versions:
Model
Description
S2-60602
MCN EXB Module with Internal 2W/4W Leased Line Modem
Certified for US, Canada, and UK operation.
Can also be used on private leased lines that are not subject to
PTT approval requirements.
S2-60655
MCN EXB-SER Module with (2) RS-232 ports
For use with external modems or digital channel banks.
The EXB modules would be inserted in the MCN network between the CHIB and
the AIB or CIB.