Figure 3 - jumper options, Table 14 - jumper definitions – CTI Products IOB I/O Interface User Manual

Page 21

Advertising
background image

IOB Hardware Reference

Option Switches and Jumpers

CTI Products, Inc.

68-11168-105

16

CA-80024-100

E1 A

E1 B

Figure 3 - Jumper Options

Jumper E1A is located across the top 2 terminals of the 6 pin terminal block. This
jumper is reserved and should not be installed.

Jumper E1B is located across the left side middle and bottom terminals of the 6
pin terminal block. Set this jumper to match the needs of your I/O system.

The remaining 2 terminals of the block are unused.

Jumper

Function

Default

E1A

Reserved

OUT

E1B
Vp Set

In for inputs pulled up to +5 Vdc.
Out for inputs pulled up to +13.8 Vdc.

OUT

Table 14 - Jumper Definitions

Because most installations require the pull-up voltage to be +13.8 Vdc, no jumper
is provided with the unit for the E1B jumper terminals. If you have an application
that requires the pull-up voltage to be set to +5 Vdc, you can order an additional
jumper by calling CTI Products Inc. and ordering part number
27-10351.

Advertising