Wiring a tib to a tsam, Force select out connections, Wiring a tib to a tsam 8.1 f – CTI Products TIB TSAM Interface User Manual

Page 20: Orce, Elect, Onnections

Advertising
background image

TIB Hardware Reference

Wiring a TIB to a TSAM

CTI Products, Inc.

68-10911-100

15

8.

Wiring a TIB to a TSAM

Table 7 provides the wiring list to connect a TIB module to a TSAM.

TIB Pin #

Description

TSAM Pin #

21

tx select 1 out >

11

46

tx select 2 out >

37

15

tx select 3 out >

12

40

tx select 4 out >

38

9

tx select 5 out >

13

34

tx select 6 out >

39

3

tx select 7 out >

14

28

tx select 8 out >

40

22

tx select 1 in <

11

47

tx select 2 in <

37

16

tx select 3 in <

12

41

tx select 4 in <

38

10

tx select 5 in <

13

35

tx select 6 in <

39

4

tx select 7 in <

14

29

tx select 8 in <

40

19

force select out >

28

1

ground

36

Table 7 - TIB <--> TSAM Connections

8.1

Force Select Out Connections

The Force Select Out pin of the TIB (pin 19) must be connected to the Force
Select In of the TSAM (pin 28) in a system with one TSAM per communication
channel.

If a system has multiple TSAMs on a communication channel (the TSAMs, are
connected together through the P103 expansion bus), the Force Select Out pins
(pin 19) of all the TIBs on that channel must be wired together and connected to
the Force Select pin (pin 28) of the MASTER TSAM.

Advertising