Earth ground rod, Power wiring, Installation – Chamberlain TAC1 User Manual

Page 10: Earth ground rod and power wiring

Advertising
background image

10

Ensure that the unit is grounded properly. The unit contains a
number of static sensitive components that can be damaged by
static discharge.

To AVOID damaging gas, power or other underground utility
lines, contact underground utility locating companies BEFORE
digging.

NOTES:
• Use a minimum of 12 gauge wire in most cases. The type and

length of the earth ground rods vary by region. Contact the
building inspector’s office in the municipality where you plan to
install the unit for correct grounding materials and installation
procedures.

• Do not ground the unit to a pedestal post (gooseneck) if one is

used.

EARTH GROUND ROD

Other Ground Sources within
12' of the unit

Green Ground Wire

Earth Ground
Rod

Ground to
Metallic Cold
Water Pipe

Ground to
Existing
Electrical
System

12 AWG Minimum

Electrical

Panel

12' Maximum

POWER

1

2

The TAC1
MUST be
grounded.

ff

OOf

f

M a in
R o o m

E u g

R

.

m

O p e r

R

.

m

E u g . D e p t .

M a n u . 1 R m

M a in D

e p t .

M a n .

u 2 R m

Air (1)
Conditioner

)

2

(

r

i

A

r

e

n

o

i

t

i

d

n

o

C

Conference

Room 1

Conference

Rm 2, 3

Refer.

Bus 1, 2, 3

Conference

Room 2

o

C

p

m .

Ser

e

v 2

o

C

p

m .

Serv

e 1

12 Vac
Power (included)

Dedicated Outlet

Dedicated 10 Amp Minimum Circuit Breaker

TAC 1

NOTE: Chamberlain is not responsible for conflicts between the information listed in the above table and the requirements of local building
codes. The information is for suggested use only. Check local building codes before installation.

POWER WIRING

The 110 Vac outlet must be dedicated to the unit only. This outlet
should be wired back to its own 10 Amp minimum circuit
breaker. This will prevent two problems:

• Other equipment cannot introduce spikes, noise, surges, or

dips into the power circuit.

• The system’s operation will not be affected if any other

equipment develops a short circuit across the power line.

Connect the transformer into a 110 Vac outlet after all
connections have been made, any other type of outlet will cause
damage to the system.

POWER WIRE TABLE

DISTANCE

AC POWER WIRE SIZE

Under 30 feet

18 AWG

30 - 75 feet

18 AWG

75 - 150 feet

18 AWG

150 - 250 feet

16 AWG

250 - 500 feet

12 AWG

INSTALLATION

>> EARTH GROUND ROD AND POWER WIRING

1. Install the earth ground rod within 12 feet of the unit.
2. Attach a 12 AWG wire to the unit ground wire with a wing nut.

Advertising