Testing, Test gate/door relays, Test the telephone connections – Chamberlain TAC1 User Manual

Page 12

Advertising
background image

12

1. Place a telephone call from the resident’s telephone to verify it

is operating properly, then hang up the phone.

2. Press the “Call” key on the unit’s keypad. The telephone in the

residence should ring.

NOTE: After the “Call” Button is pressed, the “Status” LED on the
processor board will blink during transmission.
3. To test Relay 1 have someone answer the telephone and enter

“*9” (Star + 9). The TAC1 will disconnect the call as soon as
the relay is activated. To test Relay 2 have someone answer
the telephone and enter “*5” (Star + 5). The TAC1 will
disconnect the call as soon as the relay is activated.

TEST THE TELEPHONE CONNECTIONS

TEST GATE/DOOR RELAYS

TEST RELAY 1

TEST RELAY 2

Enter 4 digit Master Code + 1 (Key).
The “1” Key indicates the Relay to be triggered.

Enter 4 digit Master Code + 2 (Key).
The “2” Key indicates the Relay to be triggered.

NOTE: Relay 1 status indicator LED will illuminate (Blue) to show
activity when triggered.

NOTE: Relay 2 status indicator LED will illuminate (Blue) to show
activity when triggered.