CABLE REQUIREMENTS

DIMENSIONS

CARTON INVENTORY

Power Supply: 12 Vac 20 VA or 16 Vdc 2.5A

Unit (unlocked) (1)
Key (1)
12 Volt AC 20 VA Plug-In UL Listed Power Transformer (1)
Manual (1)

8-3/4"

6"

3-3/4"

3/4"

1/4"

3"

3"

4-1/4"

2-3/4"

SPECIFICATIONS

>> CABLE REQUIREMENTS, DIMENSIONS AND CARTON INVENTORY

Outdoor installations require shielded cable. Non-shielded cable can be used for indoor installations ONLY.

PROCESSOR BOARD

WIRE TYPE

RECOMMENDATIONS

From the power transformer at 120 Vac outlet

2 - Conductor Cable

Shielded Only - See Power Wire Table Below

From the door strike, maglock or gate operator

2 - Conductor Cable

See device specifications for wire size

From the strike power supply (if needed)

2 - Conductor Cable

See device specifications for wire size

From the Earth ground to processor board

12 AWG copper wire,

PVC insulated

or

12 AWG copper wire,

uninsulated

Belden #9912

Belden #8011

Residence and Telco phone lines

24 AWG twisted

pair telephone wire

Shielded - Belden #9502

From the processor board

24 AWG twisted

pair telephone wire

Shielded - Belden #9502

Between processor boards on
multiple entrance installation

24 AWG twisted

pair telephone wire

Shielded - Belden #9502

POWER WIRE TABLE

NOTE: Chamberlain is not responsible for conflicts between the information listed in the above table and the requirements of local building
codes. The information is for suggested use only. Check local building codes before installation.

DISTANCE

AC POWER WIRE SIZE

Under 30 feet

18 AWG

30 - 75 feet

18 AWG

75 - 150 feet

18 AWG

150 - 250 feet

16 AWG

250 - 500 feet

12 AWG