Figure 1. The layout of a sample gate system
NOTE: Locate activation switches at
least10 ft from the gate.
1 Operator
Wire Gauges for Given Voltage
2 Control
Panel/Enclosure
110 VAC primary / 24 VAC 100 VA secondary
3 Photocell
A 2
×
18 AWG
A 2
×
18 AWG
4 Power
Switch
B 4
×
14 AWG
B 4
×
14 AWG
5
FAAC 5 Wire Cable for Master/Slave Connection and
Junction Box
C 5
×
18 AWG
C 5
×
18 AWG
6 Gate
stops
provided by built in limit switch
7
FAAC Key Activated Switch (T10)
A 2
×
18 AWG
A 2
×
18 AWG
8
Wiring to main circuit breaker
D
6
7
8
2
×
12 AWG
Advertising