3 limit switch adjustments, Setting timer basic dip settings – Controlled Products Systems Group 1150-080 User Manual
Page 22

1150-065-F-1-11
20
3.3 Limit Switch Adjustments
CLOSE
OPE
N
Push and Hold Tab
Open
Limit
Nut
Close
Limit
Nut
Close Limit LED
Open Limit LED
•
Turn power off.
•
Push and hold locking plate tab.
•
Adjust limit nuts at full open and
full close gate positions.
•
Release locking plate tab to secure limit nuts.
•
Turn power on. Cycle gate and check positions.
•
Re-adjust if necessary.
•
Start-up direction should be ON.
SW 1, switch 1.
•
Auto close timer (when turned
on) SW 1, switch 2.
•
SW 1, switch 3 should be ON.
•
SW 2, switch 3 should be ON.
Adjust from 1 second (full counter
clockwise) to approximately 23
seconds (full clockwise).
1
ON
2
3
4
5
6
7
8
SW 1
1
23
Setting Timer
Basic DIP Settings
1
ON
2
3
4
SW 2
PUSH TO OPERATE
technician use only
LIMIT
LIMIT
PART
TIME
DELAY
REV SENSE
CLOSE
REV SENSE
OPEN
1
ON
2
3
4
1
ON
2
3
4
5
6
7
8
NO
NC
EXIT
LOOP
REVERSE
LOOP
GATE FORCED