1 main terminal description – Controlled Products Systems Group 9050-080 User Manual

Page 30

Advertising
background image

9050-065-M-3-11

28

DANGER

HIGH VOLTAGE!

5.1 Main Terminal Description

Low Voltage Common

Dry Relay Contact

Earth Ground

Circuit Board Power

Circuit Board Power

Motor

Motor

Built-In Solenoid

Lock Power

Full Open

Dry Relay Contact

Standard Reverse

•

When gate is closed, this input will open gate to full position.

•

When gate is open and auto close timer Switch 2

is

turned

ON, input will re-set and hold timer.

•

When gate is open and auto close timer Switch 2

is

turned

OFF, input will close gate.

•

When gate is closing, input will reverse gate.

•

When gate is open and auto close

timer Switch 2 is turned ON, input
will re-set and hold timer.

•

When gate is open and auto close

timer Switch 2 is turned OFF, input
will prevent gate from closing.

•

When gate is closing, input will reverse gate.

•

This input ONLY functions when gate is fully

open or in the closing cycle.

•

Operation of relay is dependent on setting of switch 3.

•

When Switch 3 is turned ON, relay activates

when gate is in the full open position.

•

When Switch 3 is turned OFF, relay is

activated when gate IS NOT closed.

Relay contacts can be set for Normally Open (NO) or
Normally Closed (NC) operation.

Contact rating is 1 amp maximum at 24-volts DC.

8

NC
NO

4702-010

12

11

10

9

8

7

66

5

4

3

2

1

9

10

11

NC

NO

SECTION 5 - MAIN TERMINAL WIRING

24 VAC - 250 mamp. max.

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8