STEP 16

To adjust the closed position stop:
Loosen both nuts on the Closed Position
Adjustment Bolt.

Adjust the Bolt to stop the gate’s closing at
the proper position:

• Turning the Bolt clockwise allows the gate

to close later.

• Turning the bolt counterclockwise causes

the gate to close earlier.

Upon obtaining the desired closed position,
tighten both nuts securely against the
Primary Drive Arm.

STEP 17

To adjust the open position stop:
Loosen the Open Position Adjustment Bolt.

Rotate the Open Position Stop so that it
bumps against the Secondary Drive Arm at
the desired position:

• Rotating the Stop to minimum position

allows the gate to open further.

• Rotating the Stop to maximum position

causes the gate to open less.

Upon obtaining the desired open position,
tighten Open Position Adjustment Bolt
against the Open Position Stop.

Primary

Drive Arm

Closed Position

Adjustment Bolt

Secondary

Drive Arm

Open Position

Stop

(rotate to adjust)

Open Position

Adjustment Bolt

Limit Setup Procedure