Ram 50 gb, Dip switch configuration, Dip switch “a” dip switch “b – Controlled Products Systems Group RAM-50GB User Manual

Page 12

Advertising
background image

10

RAMSET

www.ramsetinc.com

RAM 50 GB

DIP SWITCh CONFIGURATION

“Intelligate” Control Board

Figure 11

DIP SWITCH “A”

DIP SWITCH “B”

Dip Switch “A” 4 - 1/2 hP ERD

Dip switch A4 works with Dip switch B8

DIP A4

B8

Sensitivity

OFF

OFF

Most Sensitive

ON

OFF

1/2 Hp — Medium Sensitivity

OFF

ON

3/4 Hp — Medium Sensitivity

ON

ON

Least Sensitive

Dip Switch “B” 8 - 3/4 hP ERD

Dip switch B8 works with Dip switch A4

DIP A4

B8

Sensitivity

OFF

OFF

Most Sensitive

ON

OFF

1/2 Hp — Medium Sensitivity

OFF

ON

3/4 Hp — Medium Sensitivity

ON

ON

Least Sensitive

Dip Switch “B” 2; “PRE WARN”

Used with jP2 “Relay Connections”: pins 7 & 8.

Triggers a relay, for an alarm or light (not included), for 3 sec-

onds before the gate will move in any direction.

Sw.

Function:

ON Triggers the relay on jP2 pins 7 & 8 for 3 seconds.

OFF Regular working conditions

Dip Switch “B” 3; “CONSTANT WARN”

Used with jP2 “Relay Connections”: pins 7 & 8.

Triggers a relay, for an alarm or light (not included), to be ac-

tive anytime the gate is in motion.

Sw.

Function:

ON Triggers the relay on jP2 pins 7 & 8 while the gate

is moving

OFF Regular working conditions

Dip Switch “B” 1; Not in use at this time.

Leave in the ‘Off’ position.

Dip Switch “B” 4,5,6 & 7; Not in use at this time.

Leave in the ‘Off’ position.

Dip Switch “A” 1, 2 & 3;

AUTOMATIC TIMER TO CLOSE GATE

‘0’ is “OFF”

‘1’ is “ON”

Switch 1 2 3

Gate Open Duration:

1 1 1

60 seconds

1 1 0

45 seconds

1 0 1

30 seconds

1 0 0

15 seconds

0 1 1

10 seconds

0 1 0

05 seconds

0 0 1

00 seconds

0 0 0

Disabled - command required to close

Advertising