RAM 300

RAMSET

15

www.ramsetinc.com

Terminal # 1 - COMMON
Low voltage common.

Terminal # 2 - REv LOOP:
Stops the gate from closing. If the gate is open, it
holds the gate open. If the gate is closing, it stops
and reopens the gate. If the gate is closed, the gate
will remain closed. The function can be altered with
Dip Switch “C” 4 (see “Dip Switch Configuration”).
Used with loop detectors, photo eyes, safety
edges…etc. Becomes active with a closed contact
to common.

Terminal # 3 - CLOSE
Closes the gate. Used with three button stations or
pushbuttons. Becomes active with a closed contact
to common.

Terminal # 4 - FIREBOx
Opens the gate. Used with fire department key
switches & controls. Opens with closed contact to
common. Closes immediately when closed
contact on common is removed.

Terminal # 5 - ExIT
Opens the gate. Used with loop detectors, photo
eyes, keypads, phone entry systems, three-button
stations…etc. Becomes active with a closed contact
to common.

Terminal # 6 - PhANTOM
Keeps the gate open when the open limit switch
is activated. Used with loop detectors. Becomes
active with a closed contact to common.

Terminal # 7 - RADIO
Operation depends on dip switch “C” 3 (See “Dip
Switch Configuration”). Used with an RF receiver or
pushbutton. Becomes active with a closed
contact to common.

Terminal # 8 - EDgE
When triggered the gate will stop. The gate will
remain stopped until the detector is cleared.
Once the detector is cleared, the operator will
resume normal operation. If triggered twice before

reaching a limit switch, the alarm will sound for
6 minutes and the control board will not accept
any commands. After the 6 minutes the 24 VDC is
removed from the alarm connection and the board
resets to normal operation.

Terminal # 9 and 10 - LIMIT 1 & LIMIT 2
Direction depends on Dip Switch “C” 7 (See “Dip
Switch Configuration”). Stops the motor from
moving in one direction. These wires are preset in
factory and should not be moved. Becomes active
with a closed contact to common.

Terminal # 11 and 12 - COMMON
Low voltage common.

Terminal # 13 - +24 vAC
Provides 24 VAC for peripheral accessories.

Terminal # 14 and 15 - MAg (-) & MAg (+)
Supplies 24 VDC to a Magnetic Lock when the gate
is closing or closed. If gate is opening or opened,
then no power is supplied. Leave open if not used.

Terminal # 16 - M BRAkE
Used ONLY on the Ram 50 Operator. If while the
gate is closed someone or something tries to
manually open the gate without a proper signal
(keypad, exit loop, radio signal…), the motor will
lock up for 6 minutes. After the 6 minutes, the
operator will then secure close the gate.

Terminal # 17 and 18 - MOTOR 1 & MOTOR 2
Supplies power to the motor. Direction depends on
Dip Switch “C” 7 (see “Dip Switch Configura-tion”).
These wires are preset and connected in the factory
and should not be moved.

Terminal # 19 and 20 - AC hOT & NEUTRAL
110 VAC or 220 VAC to power the operator. Voltage
is predetermined at factory and cannot be changed
by the installer or technician.