Supplemental Regulator Unit

For RCX-88 and RCX-128 Systems that include the ALL CALL Feature

- INSTRUCTIONS -

NOTE:
Only wiring concerning the supplemental
regulator unit is shown here. For complete
installation and wiring information, please see
the complete RCX Installation instructions.

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX: (425) 455-0071

The RCX-88 and RCX-128 Systems have the All Call feature as an option. This option requires
more power than the standard CEU provides. The PAA-100F Supplemental Regulator Unit
provides the necessary power to operate the system and the All Call feature. This unit replaces
the HR-10-12 power source that comes standard in the RCX-88 and RCX-128.

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

TOLL FREE FAX LINE:

(800) 832-3765

paa-100f.vsd

121997jd

INSTALLATION:
1. Locate existing HR-10-12 at the top of the RCX-88 or RCX-128.
2. Mark wires with terminal locations before disconnecting, then disconnect and remove the unit.
3. Remove the aluminum plate from the bottom of the HR-10-12 and reattach it to the bottom of the
PAA-100F. Install the new regulator unit in place of the original one.
4. Reconnect the wires to the PAA-100F in the same way that they were connected previously.
Note some of the terminal definitions are labeled slightly differently, but they have the same function.

Replace with PAA-100F and

connect as follows:

TOP OF RCX-88 or RCX-128
EXISTING:

+S
+V

-V
-S

GND

ACL

ACV

Wht

Blk

Grn

Wht
Wht

Blk

Grn

Wht
Wht

+S

+

-

-S

FG
AC
AC

Wht

Grn

Wht
Wht

Existing HR-10-12 Wiring:

TOG

CNT

NEW:

Blk

Blk

Grn
Wht
Wht

Multi-pin male connector on

right side -- solder middle

two pins together with

jumper wire.

ADD JUMPER:

Inside CEU on mother board

(rear vertical plane)

GND
Vadd

12V

Install
jumper

Connector
attached here

No Connector
attached