Step 1-mounting the unit, Step 2-system connections – American Access Systems Advantage DKLP - Metal - 19-100(i) User Manual

Page 4

Advertising
background image

Page 4 American Access Systems / Security Brands, Inc.

STEP 1-MOUNTiNG THE UNiT

Page 3 tells you what tools and instruments you will need to install your unit and presents a parts check list. Make sure
to have all the tools listed. Upon opening the box, check off the items enclosed with the unit. If any items are missing
from your unit, contact American Access Systems immediately.

Mounting the unit to your own pedestal
Your unit comes with a square mounting flange found in the bottom of the box along with four carriage bolts and four
hex nuts. The square mounting flange may be welded to your pedestal and the flange bolt pattern will align with the
back of the unit. Place the unit up to the flange and insert the carriage bolts from the back side. Secure the unit to
the flange by tightening down the hex nuts with a 7/16” socket.

Mounting the unit to an AAS gooseneck (18001) or double height (18003)pedestal
Locate the four carriage bolts and four hex nuts found inside the unit box. Place the unit up to the pedestal flange
and insert the four carriage bolts from the backside. Secure the unit to the pedestal using the four hex nuts and a
7/16” socket. The extra square mounting flange may be discarded.

Mounting the unit to an AAS diagonal pedestal (18002)
Locate the four bolts provided with the pedestal. Place the unit up to the pedestal so that the unit hole pattern aligns
with the pretapped pedestal bolt holes. Insert the pedestal bolts from the inside of the unit and tighten down with a
7/16” socket. The extra square mounting flange, four carriage bolts, and four hex nuts provided inside the unit box
may be discarded.

STEP 2-SYSTEM CONNECTiONS

Study the WIRING COLOR CODE chart below and then proceed to the hookup steps.

ACU HARNESS COLOR CODES

RED

(+) POSiTiVE

6-12 volts DC

BLACK

(-) NEGATiVE

Common

LATCH CONTACTS

BROWN

RELAY COMMON

ORANGE

NORMALLY OPEN

BLUE

NORMALLY CLOSED

SHUNT CONTACTS

(Used for external alarm)

GRAY

RELAY COMMON

ViOLET

NORMALLY OPEN

YELLOW

NORMALLY CLOSED

Advertising