Zündungsfunktion (Ignition) 

The device is capable of being externally started by using an additional signal input. This function is well known 
from the automotive industry (switch‐on by using an ignition contact). The device is here continuously supplied 
with a 24 V DC power supply, and only if the additional signal is present at the ignition contact, e.g. as a result of 
turning the ignition key of the forklift, the computer is switched on or the blocking is released. This function 
protects the system from unauthorised use, and saves energy by using the battery of the vehicle only in 
connection with the vehicle being used, at the same time, if the device is installed onboard of vehicles or other 
mobile and battery driven equipment. This function can be configured by using the Ignition Key Locking software 
tool. It allows you, for instance, to shut down the computer after expiry of a timer once the voltage is no longer 
present at the ignition contact. 

Preassembled supply cables that allow the use of this ignition function are available from ads‐tec. 

 

Note: 

Switching the device ON or OFF by using the Power button will override the ignition 
function. That means, if the device is switched off by using the Power button, the 
system is shut down and can be restarted by using the Power switch after that, but 
can then also be restarted by using the ON/OFF function of the ignition.

 

 

Warning: 

The ignition signal works with a threshold value of 5V DC. The voltage must never exceed 
the maximum voltage of 36 V DC! Risk of destruction! 

Do not use the device onboard of vehicles with more than 24 V DC system voltage without 
any voltage adaptation for the ignition contact! Risk of destruction! 

 

 

Note: 

The ignition function must never be used together with the autostart function, at 
the same time!

 

 

Note: 

The ignition function is available with most operating systems.

 

Pos: 27 /Datentechnik/Schnittstellen/Autostart/Autostart für VMT 60xx @ 1\mod_1246631044840_6.doc @ 5885 @

6.3 Autostart (S1) 

The autostart function allows the automatic start‐up of the device upon application of the supply voltage of 24 V 
DC. 

 

Note: 

The Autostart switch in the service slot must be set to ON in order to use this 
function.