OWNER'S MANUAL

MVXA SERIES
MULTI-AMPLIFIED MONITOR PANEL

6

MVXA Series Back Panel View (Rear Panel Cover Removed)

Shields and Grounding

The MVXA requires a solid "earth ground" connection. The unit itself is internally grounded from the circuit board
to the chassis and should receive a good "earth ground" under most mounting conditions. If the unit is not rack
mounted or the powder-coat paint is interfering with the case grounding, then one of the "S" ground screw terminals
should be taken directly to earth ground.

Grounding is by nature complex and often requires a variety of options. If the direct connection to earth ground is
not desired. Contact technical support on how to properly break the shield to earth ground connection.

11

10. Power Input

The MVXA Series requires a 15-20 Volt AC or DC

power supply. A 15VAC tabletop supply is included

with the unit. The provided power supply may only

be connected to a 110/120VAC power receptacle.

11. Speaker/Headphone Disconnect Jumper

When an external speaker or line level device is

connected, the internal speaker and headphone jack

continue to operate. If this is not desired, the

speaker/headphone disconnect jumper may be

moved to the off position to bypass the internal

speaker and headphone jack. See Internal Speaker

Examples on the Front Panel View.

12. Speaker Out Terminals

An external speaker may be connected to the

speaker out terminals for local or remote monitoring

The external speaker may be operated with or

without the internal speaker (see internal speaker

examples on the Front Panel View). The output

level is adjusted by the front volume control. The

external speaker level output is rated at 3 Watts into

8 Ohms with a minimum 4 Ohm load.

13. Line Level Out Terminals

The MVXA includes a line level output. The output of

the line level device is not affected by the volume

control.

14. Lacing Rail

The MVXA's bottom panel includes many wire

management features. Holes are located along

the back of the panel for tie wrapping. These holes

are spaced 2" apart to allow the use of readily

available hardware handles or lacing bars. There

is also a

3

4

" opening along the entire length of the

bottom panel for wire access. The rear panel cover

is also equipped with knockouts on either end for

wire

management.