Agri-Fab 45-0405 User Manual

Page 6

Advertising
background image

6

45_0382Fig8

1/8 x 3/4 in.

COTTER PIN (K)

FLOW

CONTROL

ROD

FLOW

CONTROL

LEVER

45_0382Fig11

POSITION 5

ADJUSTABLE

STOP

1/4 in. NYLOCK NUTS

FIGURE 11

FIGURE 8

12. Insert the end of the flow control rod through the slot in

the flow control mounting bracket and through the hole
in the flow control lever. Secure with a 1/8 in. x 3/4 in.
cotter pin. See figure 8.

45_0382Fig10

45_0382Fig10

ADJUSTABLE

STOP

OFF

FIGURE 10

14. Adjust the position of the flow control mounting bracket

(figures 10 and 11):

a. Set the adjustable stop at “5.” Latch the flow control

lever against the stop. Verify that the closure plate
has opened about halfway. See figure 10.

b. If closure plate is not open halfway, adjust the position

of the flow control mounting bracket until the closure
plate is open about halfway at “5” and still closed when
the lever is in the “OFF” position. Carefully tighten
the 1/4 in. nylock nuts. Do not deform the slots in the
flow control mounting bracket.

c. Push the flow control lever to the “OFF” position

and ensure the closure plate closes completely.
See figure 11.

13. Install the adjustable stop on the slot in the top of

the flow control mounting bracket. Secure with the
1/4 in. x 3/4 in. carriage bolt, a nylon washer, a 1/4 in.
flat washer and the nylon wing nut. See figure 9.

45_0382Fig9

45_0382Fig9

ADJUSTABLE

STOP (O)

1/4-20 WING NUT (M)

1/4-20 x 3/4 in.

CARRIAGE BOLT (D)

1/4 in. WASHER (F)

FIGURE 9

Advertising