Operating instructions, Power up and boot sequence, Power down – Lectrosonics HM User Manual

Page 8: Standby mode, Compatibility mode screen, Selecting the audio polarity, Automatic power restore

Advertising
background image

HM

LECTROSONICS, INC.

8

Operating Instructions

AUDIO

Button

FREQ

Button

Modulation

LEDs

PWR LED

UP Arrow

DOWN Arrow

Power Up and Boot Sequence

1) Ensure that good batteries are installed in the unit.
2) Simultaneously press and hold the AUDIO and

FREQ buttons. Continue holding the buttons until

On and the characters 1, 2, 3 have appeared. The

boot sequence will then initiate.

Initial Power On

Timer Screen

As the unit turns on, the

Modulation LEDs and PWR

LED all glow red, then green,

and then they revert to normal

operation.

The LCD displays a bootup sequence which con-

sists of four screens:

Company Name:

Lectro

Frequency Block (bXX) and

Firmware Version (rX.X):

b21r1.1 (typ)

Compatibility Mode:

CP 400 (typ)

Audio:

Aud 12 (typ)

Power Down

Simultaneously press and hold the AUDIO and

FREQ buttons. Continue holding the buttons until

OFF and the countdown characters 3, 2, 1 have ap-

peared. The unit will then power down.

Initial Power Off

Timer Screen

If the AUDIO and FREQ

buttons are released before

the LCD goes blank at the end

of the countdown, the unit will

not turn off. Instead, it will stay

energized and the LCD will return to the previous

screen.

NOTE: If batteries are removed or reach the end

of life while the unit is turned on, the unit will turn

back on with a brief, simultaneous press of the

AUDIO and FREQ buttons. The counting sequence

will not be displayed in this instance.

Automatic Power Restore

The firmware will remember the power on/off state and

the settings when batteries reach their end of life or are

removed. When fresh batteries are installed, the unit will

reboot and return to the previous settings without the

need to press any buttons. This only works when the

unit is fully on and transmitting.

It does not work in the

Standby Mode.

Standby Mode

Standby Screen

Standby Mode allows you to

verify or change the transmit-

ter’s operating frequency or

audio input level without

transmitting a signal. Quickly press and release both the

AUDIO and FREQ buttons simultaneously to enter and

exit this mode. The characters

rF OFF will appear on

the LCD while the unit is in the standby mode.

Compatibility Mode Screen

Hold down the UP arrow

button while powering up the

unit to enter the Compatibility

Mode screen. Use the UP or DOWN arrow buttons to

select one of six compatibility modes:

Note: RF transmission is prevented while selecting

Compatibility Modes. Also, the HM exits this

screen to the Standby Mode.

• 400 - For Digital Hybrid Wireless

®

receivers.

• 200 - For Lectrosonics 200 Series receivers.
• 100 - For Lectrosonics 100 Series receivers.
• 3 - (Mode 3) For non-Lectrosonics analog receivers.

Contact the the factory for details.

• IFB - For Lectrosonics IFB receivers.
• 6 - (Mode 6) For non-Lectrosonics analog receivers.

Contact the factory for details.

While in the compatibility mode screen, pressing either

the AUDIO or FREQ button exits to standby mode. To

power off from the compatibility mode screen, press

and hold AUDIO and FREQ together.

Selecting the Audio Polarity

Audio Polarity can be

reversed as needed

from the setup screen

Hold the UP arrow in and

press the AUDIO and FREQ

buttons together to enter the

setup mode. The display will

first enter the

CP (compatibility

mode) setup screen.
Press either the AUDIO or

FREQ button to enter the

AP

(audio polarity) setup screen.

Use the UP and DOWN arrows

to select the desired polarity. The character

P denotes

“positive” polarity and the character

n denotes “nega-

tive” polarity.

NOTE: The audio polarity can also be reversed at

the output of most Lectrosonics receivers.

Advertising