3.8

Standby Listen Mode

In the standby listen mode the IC monitors the coil input with a very low current consumption.
The automatic gain control is switched off and the gain is set to the maximum value. The
N_DATA and the N_WAKEUP output are set to a high level.

Before the controller enters its standby mode after the communication, it should activate the
standby listen mode of the ATA5283 with a reset signal. This measure ensures that the IC
enters the power saving standby mode and that the IC wakes the controller correctly with the
next preamble signal.

3.9

Applications

Figure 3-6

shows a typical TPM application of the ATA5283. Combined with the antenna reso-

nant circuit the ATA5283 is used as wake-up receiver for the microcontroller and the connected
temperature- and pressure-sensor.

Note:

To avoid supply voltage ripples to affect the microcontroller, an RC filter (R1 = 100

, C1 = 10 nF)

is recommended.

Figure 3-6.

Application

5

7

6

1

RESET

R1

LA

CA

433 kHz

125 kHz

C1

Central

board

controller

T5743

UHF Rx

UHF Tx

Antenna

driver

ATA5275

Micro

controller

N_WAKEUP

N_DATA

Vref

Temp.

sensor

Pressure

sensor

2

3

8

4

ATA5283

ATAR862

Amplifier

with
AGC

Advertising