Locking or unlocking the control panel – Lectrosonics SMQ User Manual

Page 11

Advertising
background image

Super-Minature Belt Pack Transmitter

Locking or Unlocking the Control Panel

The Lock mode protects the transmitter from accidental
changes to its settings.

1. Ensure the SM setup is complete (operating

frequency, audio level, Compatibility Mode, sensitiv­
ity to remote control).

2. Simultaneously press both

the Up and Down arrow

Loc

buttons to start the Lock
timer. When the timer

Control Panel Locked

reaches zero, “Loc” is
displayed and the controls are locked.

Important: Once the transmitter is locked, it
cannot be unlocked or powered off using the
buttons. The only ways to unlock a locked
transmitter are to remove the battery or unlock
it via the remote control. The remote control
will work only if the transmitter was previsouly
configured to respond to the remote control.
Lock mode does not persist when the power is
off.

Rio Rancho, NM