Setup with the lcd, Audio screen, Frequency screen – Lectrosonics SMa User Manual

Page 7: Compatibility mode screen, Turning the power on, Turning the power off, Entering the standby mode, Lock/unlock screen

Advertising
background image

Super-Minature Belt Pack Transmitters

Setup with the LCD

Six screens are used to set up and operate the SM.

These screens are used to set the operating frequency,

adjust the audio input level, select the Compatibility

Mode or lock the control panel and power down the

transmitter.

Audio Screen

The Audio screen is used to

adjust input gain from 0 to +44

dB, and the low frequency roll-

off from 35 to 150 Hz. Repeat­

edly pressing the AUDIO button

toggles back and forth between the two displays. Press

and hold the AUDIO button and use the Up and Down

arrows to make adjustments.

Frequency Screen

The Frequency Screen dis­

plays the operating frequency

in MHz or as a two-digit

hexadecimal number that cor­

responds to the equivalent

Lectrosonics Frequency Switch

Setting. Pressing the FREQ button toggles between the

two displays.

Compatibility Mode

Screen

Holding down the Up arrow but­

ton while powering up the SM

opens the Compatibility Mode

and Power setting screens. Repeated pressing of the

FREQ or AUDIO buttons toggles between the Compat­

ibility Mode and Power screens.

Note: RF transmission is prevented while selecting

Compatibility Modes and Power level.

Use the Up and Down arrow buttons to select the de­

sired compatibility mode:

• 400 - for all Lectrosonics 400 Series Digital Hybrid

Wireless

receivers, including the Venue. This mode

offers the best audio quality.

• 200 - for all Lectrosonics 200 Series receivers.
• 100 - for all Lectrosonics 100 Series receivers.
• 3 - (Mode 3) for non-Lectrosonics analog receivers.

Contact the factory for a list of compatible receivers.

• IFB - for all Lectrosonics IFB receivers.
• 6 - (Mode 6) for non-Lectrosonics analog receivers.

Contact the factory for a list of compatible receivers.

To power off from the compat­

ibility mode screen, press and

hold AUDIO and FREQ to­

gether.

Initial Power On

Timer Screen

Turning the Power On

With the power turned off, simultaneously pressing

and holding the AUDIO and FREQ buttons displays a

timer with numerals on the right. The numerals count

up from one and the boot sequence begins when the

count reaches three. “LECtro” is displayed as the boot

sequence begins. If either button is release prior to the

screen reaching numeral three,

the unit will enter the Standby

Mode with no RF output (see

Standby Mode below).

Initial Power Off

Timer Screen

Turning the Power Off

With the unit turned on, simultaneously holding the AU­

DIO and FREQ buttons starts a countdown timer with

numerals on the right. The screen counts down from

three and the transmitter turns off when it reaches zero.

Releasing either button prior to the Power Off Timer

screen indicating zero returns

the unit to normal operation and

displays the previous screen.

Standby Screen

Entering the

Standby Mode

With the power turned off, pressing the AUDIO and

FREQ buttons for about one second places the unit in

Standby Mode. In this mode the RF output is turned off

so all setup adjustments can be made without interfer­

ing with other systems operating in the same location.

The screen displays “rf OFF” to remind the user that the

unit is not transmitting.
Holding the FREQ button in Standby Mode displays the

current operating frequency of the transmitter. The op­

erating frequency can be changed by holding the FREQ

button and pressing either the Up or Down button.

Release the FREQ button, then press and hold it again

to toggle the display between frequency in MHz and the

hex code corresponding to the equivalent Lectrosonics

Frequency Switch Setting.
Holding the AUDIO button in Standby Mode displays

the current audio input level setting. This level can be

changed by holding the AUDIO button and pressing

either the Up or Down button.
Quickly pressing both the FREQ and AUDIO buttons

simultaneiously when the unit is

in Standby Mode powers off the

transmitter.

Lock/Unlock Screen

Simultaneously pressing and

holding both the Up and Down

arrow buttons during normal operation starts the Lock

timer. The timer starts at three and counts down to zero.

Rio Rancho, NM

7

Advertising