Troubleshooting, Symptom possible cause – Lectrosonics UT400 User Manual

Page 16

Advertising
background image

UT

Troubleshooting

SYMPTOM

POSSIBLE CAUSE

UT POWER LED OFF

1) Battery is inserted backwards.
2) Battery is dead, or too low to be used.

UT MODULATION LEDs OFF

1) Audio Level control turned all the way down.
2) Battery is in backwards. Check Power LED.
3) Mic capsule is damaged or malfunctioning.

Contact the factory for repair .

4) Attenuator on VariMic™ preamp board is set for

too much attenuation.

RECEIVER RF INDICATOR OFF

1) UT not turned on.
2) Battery is dead or installed backwards
3) Receiver antenna missing or improperly positioned.
4) UT and receiver not on same frequency. Check labels on UT and

receiver to be sure they are operating on the same frequency block.

5) Make sure the transmitter and associated frequency switch settings

are in agreement.

6) Operating range is too great.

NO SOUND BUT RECEIVER AUDIO LEVEL METER INDICATES SOUND

1) Receiver audio is muted. (Unmute receiver.)
2) Receiver audio output levels set to low.
3) Receiver audio output is disconnected or cable defective

or miswired.

4) Sound system or recorder input is turned down.

DISTORTED SOUND

1) UT Audio Level control set too high. Speak or sing into the UT and

check the UT Audio Level LEDs and corresponding indicators on

the receiver.

2) Receiver output level may be too high for the sound system or

recorder input.

3) If audio level is all the way down, it may be necessary to increase

attenuation in the capsule. Refer to the “Preamp Level Control”

section on page 8.

3) Excessive wind noise or breath “pops.” Microphone may require

an additional wind screen.

4) UT Frequency Switches set incorrectly.
5) RF feedback getting into VariMic

TM

mic capsule. Ensure that the

windscreen is present and screwed down snugly.

6) Compatibility Mode mismatch between transmitter and receiver.

HISS AND NOISE -- AUDIBLE DROPOUTS

1) UT Audio Level control set too low.
2) Receiver antenna missing or obstructed.
3) Operating range too great.
4) UT Frequency Switches set incorrectly.

EXCESSIVE FEEDBACK

1) UT Audio Level control set too high. Check level adjustment,

reduce receiver output level, or both.

2) Microphone too close to speaker system.
3) Move microphone closer to the user’s mouth and lower the

sound system volume.

LECTROSONICS, INC.

16

Advertising
This manual is related to the following products:

UT