The RCW-DESK is connected to the hybrid via the
DB-9

Remote Control Port. The wiring configuration

has the following format:

Pin 1 (CS) - Connect/Disconnect Switch function ­
connects or disconnects the telephone hybrid to/
from the phone line.

Pin 2 (PS) - Privacy Switch function - mutes the
transmitted audio to allow private conversation.

Pin 3 (VU) - Volume Up Switch function - increases
the receive volume level by 1 dB until volume limits
are reached (the range of adjustment is set by the
Volume Limit dip switch settings).

Pin 4 (VD) - Volume Down Switch function - de­
creases the receive volume level by 1 dB until volume
limits are reached (the range of adjustment is set by
the Volume Limit dip switch settings).

Pin 6 (PL) - Privacy LED - indicates if the privacy
function is currently active.

Pin 7 (CL) - Connect/Disconnect LED - indicates if the
telephone hybrid is connected (steady ON), discon­
nected (steady OFF), is in the process of being
connected (series of blinks), or if one of the volume
switches is being pushed (one blink).

Pin 8 (GND) - Ground connection.

LECTROSONICS

PRIVACY

CONNECT

UP

DOWN

TELECONFERENCE

VOLUME

RCW-DESK

Actual Size

REMOTE CONTROL

CONNECT

PRIVATE

VOL UP

VOL DOWN

PRIV LED

CONN LED

COMMON

1
2
3
4
6
7
8

The DB9 plug connects into the jack on the rear

panel of the telephone hybrid.

Controls:

Soft-touch switches

Functions:

• Connect/disconnect
• Privacy on/off
• Volume Up
• Volume Down

Connecting cable:

9 ft. long with molded DB-9 plug

Dimensions:

2.8 x 4.6 x 1.3 inches
including rubber feet

Construction:

Machined aluminum housing

Finish:

Electrostatic powder coating and
anodize. Nomenclature is laser
engraved for durability.

RDESKTD-1002

®

581 Laser Road NE - Rio Rancho, NM - 87124 USA
tel (505) 892-4501 or (800) 821-1121 - fax (505) 892-6243
Web: www.lectrosonics.com E-mail: [email protected]