Dimensions and specifications, Specifications, Dimensions – Liquid Controls SP714-S2i User Manual
Page 4
Advertising

dImensIons and sPecIfIcatIons
Weight
• 1.2 lbs (0.54 kg)
Materials of Construction
Housing
• Aluminum Alloy ADC12
• Powder Coat: Corro-Coat PE 74-141 Polyester
Adapter (to turbine meter boss)
• Stainless Steel
Cable Entry
• ½"-14 NPT
Temperature Range
Operating
• -40 to 176 °F (-40 to 80 °C)
Storage
• -76 to 257 °F (-60 to 125 °C)
Specifications
Input Voltage
• 6-28 VDC; 83 mA maximum @ 24 VDC
• Protected against polarity reversal
Signal Input
Frequency
• 2 kHz maximum over operating temperature in all modes
Amplitude
• 10 mV p-p minimum sine or square wave
Impedance
• 50 KΩ
Sensitivity Field
• Adjustable by potentiometer (R1)
Output Signal Characteristics