Display flags and led warning interpretation – Liquid Controls HML110 IOM User Manual
Page 12

HML 110
12
110_EN_LC_5_3_6X.doc
DISPLAY FLAGS AND LED WARNING INTERPRETATION
FLAG INTERPRETATION
FLAG
DESCRIPTION
M
Alarm max activated
m
Alarm min activated
!
- Interruption coils circuit
- Segnal error
- Empty pipe
C
Calibration running
S
Simulation
Pulse output saturation (reduce
TIME PULSE )
FLAGS
LED
LED INTERPRETATION
PERMANENT LIGHT: initialisation
FLASHING LIGHT ( 1 sec.): normal function
FLASHING LIGHT (<1 SEC.): alarm on
The LED signals the alarm status only if the display shows one of the
suitable visualisation screens as shown on page 14
At ‘Power on’ of the converter, the user will see the following display screen. In the top right
hand corner there may be a range of symbols. The symbols can be interpreted from the table
below. Interpretation of the flashing LED can be made from the LED Interpretation table at the