Specifications

Display

•

Total
•

8 digit 5.40mm high LCD (continuous display)
•

Batch total (magnetic reset)

•

Grand total (no reset)

•

Rate
•

5 digit 8.66mm high LCD (continuous display)

•

Range over/under limit indication

•

Refresh rate: Multiple depending on power
mode (1/16s, 1/8s, 1/4s, 1s, 0.5s)

•

Backlighted green w/ LED (magnetically activated
and timed)

•

Dual segment low-battery warning

•

Maintenance due warning

•

Temperature range warning

Power:

•

Internal: D Lithium battery
•

Battery life: Various: typical per power mode:
1: 1yr, 2: 1yr; 3: 3.6yr; 4: 3yr; 5: 8yr

•

External DC: 5 to 48VDC +/- 2 VDC reverse
polarity protected (Max: 12mA w/ backlight)

•

Loop: requires 7VDC of loop supply
•

Loop powered from the 4-20mA loop input
(non-isolated)

K-Factor range

•

Pulses per gallon: 0.0000001 to 999999

Signal Input (flow)

•

Frequency: 0-3000Hz

•

Impedance: 10k ohms

•

Magnetic
•

Sensitivity: 50mV-36V (field adjustable) sine
or square wave

•

Modulated carrier
•

Carrier frequency 50kHz (requires external
power or loop power)

Compensation Input

•

Temperature - RTD
•

Two wire 10k ohm

•

Coefficient of Thermal Expansion method

•

Frequency
•

Linearization table 2 to 20 points

Engineering Unit Conversions

•

Pre-programmed units: Gallons, Liters, Ft

3

, M

3

,

Pounds, BBL, KG (custom weight available)
•

Custom units available with given units/gallon

•

Rate and Total may have separate unit displays

Decimal Locations

•

Total: Two places (and x10, x100)

•

Rate: Three places (and x10, x100), autorange

Time Base

•

Rates can be displayed in units per second,
minute, hour, day, and custom (in seconds)

Outputs

•

Factored Pulse (Max: 150mA, 30VDC, 150mW)
•

Opto-isolated open collector output

•

Frequency or fixed pulse width (1, 2, 5, 10,
50, 100, & custom ms) output setting

•

Output pulse Divider: 1, 2, 5, 10, 50, 100,
1000, & custom

•

Alarm (Max: 150mA, 30VDC, 150mW)
•

Programmable opto-isolated open collector
output

•

Can be used to control totalization

(Max values at 25°C. Max combined Pulse/Alarm
output power: 190mW @ 25°C, 32mW @) 65°C)

•

Rate (4-20mA)
•

Factored rate to current loop output

•

Programmable low and high

•

Fully isolated (unless loop powered)

•

Loop Voltage limit: 7-36VDC

Accuracy

•

Display: ±0.01% reading (rate) or ± 1 count (total)

•

Analog output: ±0.025% of fs @20°C

•

Digital output: ±1 count

Environmental

•

Operating: -30 to 65°C (-22 to 150°F)

•

Storage: -40 to 85°C (-40 to 185°F)

Enclosure

•

Explosion Proof Aluminum
•

FM Approved, CSA Certified

•

Class I, Division1, Groups B, C, & D

•

Class II, Division 1, Groups E, F, & G

•

NEMA 4X, IP66

•

All openings ¾” FNPT

•

Weight: 2.5lbs.

•

Mount: Directly on flowmeter or Wall mount

Compliance

•

CE 0575

•

ATEX Ex II 2 G Ex d IIC T6 Gb (X and WX
enclosure types only)

•

DNV-2008-OSL-ATEX-19241X

Communications

•

RS-232

Datalogger

•

Up to four triggers (including timer)

•

Up to seven system values

•

Real-time clock

•

RS-232 or Internal SD/MMC Flash media card

Other features

•

EEPROM setup storage (>100 year retention)

•

All features/settings are field programmable.
Convenient number input via 0-9 rotary switch and