Liquid Controls SP3000 User Manual
Page 9

9
1.63
RELAY OUTPUTS
One relay is provided as a flow alarm and a second is provided for the other alarm conditions.
Each has the following specifications:
Type:
Dry contact, Form C
Contact Rating:
10A at 115/230 VAC/28 VDC
Typical Relay Output Schematics:
22
23
24
1.64
AUXILIARY POWER OUTPUT
Voltage:
24 VDC regulated and filtered
Isolation:
230 VAC max
Current:
0 to 100 mA
Protection:
Short Circuit Proof
1.7
RS-232 COMMUNICATIONS PORT
(Refer to RS-232 Addendum supplied with RS-232 option)
Connector:
25 Pin Sub-D
Input Impedance:
3000 ohms to 7000 ohms
Compliance Voltage:
Output: -25 to –5 (Mark); 5 to 25 (Space); Volts
Input:
-25 to –3 (Mark); 3 to 25 (Space); Volts
Protection:
Short Circuit Proof
Protocol:
8 bits, 1 stop bit
Parity:
None (Not Monitored)
Available Baud Rates:
300, 1200, 9600
RS-232 Connector Pin Out:
Printer Busy (11)
Pins 4 and 5 are jumpered together
Pins 6, 8, and 20 are jumpered together
Ground (7)
Recieve (2)
Transmit (3)
25 24 23 22 21 20 19 18 17 16 15 14
1
2
3
4
5
6
7
8
9
10
11
12
13