4 alarm outputs – Liquid Controls IT375 User Manual
Page 25

Sponsler, Inc.
Model IT375
Intrinsic Safety Pg. 25
8.4 ALARM OUTPUTS
The low alarm and high alarm/pulse output can be connected to suitably certified devices provided the circuit is protected
with a barrier with the maximum safety parameters:
Uo = 28V
Io = 93mA
Pmax = 0.653W
The input capacitance on these terminals is 0.1uF max and the inductance is negligible.
Note: The two alarm outputs must be kept as independent IS circuits and each protected with their own barrier. It is not
permissible to connect these circuits via a common barrier.
IS CERTIFIED BARRIER
Uo = 28 V maximum
Io = 93 mA maximum
Po = 653 mW maximum
SAFE AREA
HAZARDOUS AREA
4 or 6
3 or 5
MODEL IT375
IS Certified Device
Such as an Alarm Lamp
Or IS Solenoid