To adjust the width of the laser beam rotate the front focusing ring (1). Narrowing the beam would help to
reach farther distance. Widening the beam would provide more comfortable viewing over shorter distances
and help to illuminate wider field of view.

This illuminator is supplied with a miniature adjustment key, which you can use to adjust the horizontal
and/or vertical direction of the infrared beam. To do so, you should first mount the illuminator onto your
specific night vision model and turn on the unit and this illuminator. You will then see if the illuminator beam
is in the center of the image, or not. If not, then insert the adjustment key into horizontal and/or vertical
adjustment hole (6) and gently and slowly rotate the key while viewing the image through your night vision
device until the image is aligned to your liking.

IMPORTANT:

Do not use any force when rotating the

key!

IMPORTANT:

do not try to remove the other two knobs located opposite the adjustment

holes, as doing so will render the illuminator inoperable and will void any warranty claims!
--------------------------------------------------------------------------------------------------------------------------

There are 3 versions of the laser illuminator, which differ only by the type of the mounting bracket:

Version 1 (model LN-ELIR1) has a sliding bracket and mounts onto the following Luna Optics products:
LN-PB3/LN-PB5/LN-PB7/LN-PBG1-PRO/LN-EBG1/LN-EBG1-PRO binoculars and goggles. To attach the
illuminator simply slide open the metal cover on top of the night vision unit body and insert the laser IR into
the opening. Once fully inside, tighten the Mounting Wheel (5) on the bracket.

Version 2 (model LN-ELIR2) (pictured) has a screw bracket and mounts onto the following Luna Optics
products: LN-PRS25M/LN-PRS40M/LN-EM1-MS/LN-EM1-HRS/LN-EM1-PRO/LN-ERS40M/LN-ERS45M-PRO/LDN-
ERS36M-PRO monoculars and riflescopes. To attach the illuminator simply find the accessory mount on the
body of the night vision unit and screw in the illuminator with the help of the Mounting wheel (5).

Version 3 (model LN-ELIR3) has a rail type bracket, which mounts directly onto any Weaver / Picatinny rail
and can be used in conjunction with any Gen-1, 2(2+) and 3 night vision device.
--------------------------------------------------------------------------------------------------------------------------

Technical Specifications:

Wavelength---------------------------775-795nm Dimensions ------------------------ 105mm x 26mm x 39mm
Maximum Output power------- 0.5mW (Class-I) Weight ----------------------------------------------------- 70g
Maximum viewing distance---------------- 150m Operating time (max power) -----------------------------7hrs
Viewing degree--------------------------- 0.1 – 5 Operating time (mid level power) ----------------------14hrs
Objective lens diameter ------------------ 10mm Battery ---------------------------------------- 3V Lith. CR123

-------------------------------------------------------------------------------------------------------------------------

Warnings:

1. Do not, under any circumstance try to disassemble this device – this may result in

exposure to the laser radiation level higher than Class-I and may result in
permanent eye damage.

2. Do not try to remove the protective filter in the front of the screen. It is installed

permanently and its forceful removal will result in exposure to laser radiation level
higher than Class-I and may result in permanent eye damage.

3. Do not look directly at the laser beam through any optical product. Violation of this

rule may result in eye strain and/or injury.

4. Do not point the laser directly at anyone’s eyes. Do not direct the laser at a low-

flying aircraft, helicopter or moving motor vehicle.

Failure to observe Warnings # 1 and # 2 is in direct violation of FDA Rules and
Regulations.

Failure to observe Warning # 4 may result in an accident, as well as possible arrest
and prosecution.

Luna Optics, Inc. 54 Columbus Avenue, Staten Island, NY 10304 (USA) Tel: +1-718-556-5862; Fax: +1-718-556-5869

E-mail:

[email protected]

Web:

www.lunaoptics.com

© 2012