SAFETY & WARNING INFORMATION:
OPERATING YOUR POLYESTER SYSTEM SAFELY
1. Introduction
Any tool, if used improperly, can be dangerous. Safety is ultimately the responsibility of those 
using the tool. In like manner, safe operation of polyester processes is the responsibility of those 
who use such processes and those who operate the equipment. This manual outlines 
procedures to be followed in conducting polyester operations safety. This system has been 
specifically designed for use of Polyester Resin, Gel-Coat, and Methyl Ethyl Ketone Peroxides 
(MEKP) applications. Other formulations or blends considered for use in this equipment is 
strictly prohibited without the expressed consent by Magnum Venus Plastech Inc. Magnum 
Venus Plastech cannot eliminate every danger nor foresee every circumstance that might cause 
an injury during equipment operation. Some risks, such as the high pressure liquid stream that 
exits the spray tip, are inherent to the nature of the machine operation and are necessary to the 
process in order to manufacture the end-product. For this reason, ALL personnel involved in 
polyester operations should read and understand the Safety Manual. It is very important for the 
safety of employees involved in the operation that equipment operators, maintenance and 
supervisory personnel understand the requirements for safe operation. Each user should 
examine his own operation, develop his own safety program and be assured that his equipment 
operators follow correct procedures. Magnum Venus Plastech hopes that this manual is helpful 
to the user and recommends that the precautions in this manual be included in any such 
program. Magnum Venus Plastech recommends this Safety Manual remain on your equipment 
at all times for your personnel safety. In addition to the manual, Magnum Venus Plastech 
recommends that the user consult the regulations established under the Occupational Safety & 
Health Act (OSHA), particularly the following sections: 
1910.94 Pertaining to Ventilation.
1910.106 Pertaining to flammable liquids
1910.107 Pertaining to spray finishing operations, particularly Paragraph (m) Organic Peroxides 
and Dual Component Coatings. 
Other standards and recognized authorities to consult are the National Fire Protection 
Association (NFPA) bulletins as follows: 
NFPA No.33 Chapter 14, Organic Peroxides and Dual Component Materials
NFPA No.63 Dust Explosion Prevention
NFPA No.70 National Electrical Code
NFPA No.77 Static Electricity
NFPA No.91 Blower and Exhaust System
NFPA No.654 Plastics Industry Dust Hazards
Type of Fire Extinguishing equipment recommended: Fire Extinguisher – code ABC, rating 
number 4a60bc.