Fluid Section Disassembly Procedures:


1. Remove the two Hex Nuts (F-HN-08C) from the Pump Cylinder Tie Rods (VLS-4623).

2. Slide the Foot Valve Collar, Foot Valve and Cylinder down off the Piston Rod; discard the

two O-Rings. Remove the Ball Stop (VLS-4620) and Foot Valve Spring (VLS-4621).


3. Remove and discard the 1-

1/4” Chrome Ball. Clean and inspect ball seat area of Foot

Valve.


4. Loosen Packing Nut (VLS-4607) and slide the Piston Rod out the bottom of the Outlet Body.

5. Unscrew the Piston Nut from the Piston Body. Remove the two Piston Cups, Piston Cup

Back-up and Piston Cup Spacer from the Piston Body. Discard the two Piston Cups.


6. Unscrew the Piston Body from the Piston Rod. Remove the

7/8” Ball and the

Piston Ball

Spring (VLS-4614) Discard the

7/8” Ball.


Note: Only discard the 7/8” Ball if the Repair / Seal Kit has a replacement.

7. Remove the Packing Nut (VLS-4607) from the Outlet Body

. Use a 1/4” wooden dowel to

push the Packing Set Assembly (VLS-4605) out the top of the Outlet Body. Discard the
packing set

.

Clean and inspect the Guide Bearing (VLS-4603), Female Compression Ring,

Male Compression Ring, Wave Spring (VLS-4610), and Spring Support Ring (VLS-4611).


8. Clean and inspect all parts that will be reused, replace as needed.