Owner's manual, Aa120m mixer amplifier, Rear panel description – Atlas Sound AA120M User Manual

Page 7

Advertising
background image

Specifications are subject to change without notice

AtlasSound.com

1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435

©2006 ATLAS SOUND LP

Printed in U.S.A.

00106

ATS002179 RevA 01/06

PP

OWNER'S MANUAL

AA120M MIXER AMPLIFIER

7

REAR PANEL DESCRIPTION

9. Dipswitch 1-10
Understanding the functionality of the dipswitches is key to getting the most out of the AA120M.

Whether a switch is in the "Up" or "Down" position is critical to the function of the amplifi er. Note:

Mispositioning any of these switches may cause harm to the speakers or amplifi er. We recommended
powering off the amplifi er prior to making any switch selections. Pay close attention to the assignment
chart and manual for proper settings.

Dipswitch 1- LOW CUT – When in the "ON" position, frequencies below 400Hz are attenuated

at the rate of 6dB per octave. Note: The rotary bass control is bypassed when the LOW CUT fi lter

is engaged. We suggest that when paging horns are connected to the AA120M, engage the LOW

CUT fi lter to prevent the horns from operating below their cutoff frequency. When "OFF", the

amplifi er operates full bandwidth.

Dipswitch 2- VCA – When set to the "Master" position, the VCA control port acts as a system

remote volume control, adjusting all the input channels up or down simultaneously. When set to

the

"Input 5" position, the VCA remote control port affects only the level of INPUT 5.

Dipswitch 3- PHANTOM – When set to the "OFF" position, PHANTOM POWER is turned off

on INPUTS 1-4. When set to the "ON" position, PHANTOM POWER (24VDC) is available on

INPUTS

1-4.

Dipswitch 4- Relay ACT - When set to the "CC" position, the internal relay is triggered by

contact closure (see page 32). When set to the "VOX" position, the internal relay is triggered by

audio signals at INPUTS 1-4 and INPUT 6, depending upon their rear panel switch setting.

Vox Mute

Vox Mute

Input 5

Level

Zone 3

Level

Zone 2

10

0

10

0

10

0

10

0

10

0

10

0

10

0

G

+

G

+

G

+

G

+

Unswitched Outlet

120V AC 60Hz

Max 500W

Outlet Breaker

125V AC 4A
Push Reset

120V AC 60Hz 300W

100V

70V

25V

¡

8

Com

24V DC 200mA

Relay

+

NC

C

NO

+

+

Zone 2 Out

1W 8

Zone 3 Out

¡

¡

600

Remote Mute

VCA

+

G

Sel

Bridge

In/Out

Input 6

Level

Zone 3

Level

Zone 2

10

0

10

0

Sens

Input 4

Trim

Input 3

Trim

Input 2

Trim

Input 1

Trim

Mute

10

0

10

0

10

0

10

0

10

0

10

0

10

0

Send

Off

Rcv

Send

Rcv

Off

Send

Off

Rcv

Send

Off

10

0

Zone 2 Level

Zone 3 Level

Input 3

Input 2

Input 1

Pwr In

Tape Out

1 2 3 4 5 6 7 8 910

R

Line Out

L

Input 5

Pre Out

Input 6

Input 4

Zone 2 Level

Zone 3 Level

Zone 2 Level

Zone 3 Level

Zone 2 Level

Zone 3 Level

£Ид£К>VŽÊV>ЮК Ы`°]К ˜˜ˆГ]К/8КЗx££™К
­nдд®ÊnÇȇООООКМ>Г-œХ˜`°Vœ“

77'(&C

7jbWiIekdZ77I[h_[iC_n[h7cfb_\_[h

Speaker Output 120W

Vox Mute

VoxMute

Send

Off

Rcv

CLASS 2 WIRING

Vox Mute

Chime Module

9

On

Mic

Mic

Mic

Mic

300mV

Amp Dir

Vox

Input 5

On

Relay

Act

Low Cut

Input 3

Input 4

Input 5

Input 6

Phantom

Input 1

Input 2

1

9

8

7

6

5

3

4

2

10

VCA

Off

Line

Line

Line

Tel/Line

100mV

Mix Bus

CC

Master

Off

Advertising