Chapter 3-disassembly, Removal of plv-1000, Plv-1000 disassembly procedure – Magnum Venus Plastech PRESSURE LIMIT VALVE PLV-1000 User Manual
Page 18

MAINTAINENCE AND REPAIR MANUAL
PLV-1000
MAGNUM VENUS PLASTECH
REV 1.00
APRIL 2010
PAGE 18
CHAPTER 3-Disassembly
REMOVAL OF PLV-1000
•
Caution: When removing PLV-1000, be sure to release fluid pressure from the system before
removing. System may be under pressure and could cause injury.
•
Set operating pressure at 0 psi.
•
Open recirculation valve and/or gun to purge pressure from fluid sections. Let drain until as much
fluid as possible has been purged.
•
Remove the pneumatic signal lines from the top of the PLV-1000 and remove the air fitting.
You can now remove the PLV-1000 from the unit and take it to a work area for maintenance.
PLV-1000 DISASSEMBLY PROCEDURE
Remove the Spring Housing from the Valve Body assembly. (Fig. 3.0)
FIG 3.0
Remove the Spring Retainer, Spring and O-ring from the Valve Body. (FIG 3.1)
FIG 3.1