Magnum Venus Plastech HIS Troubleshooting Manual User Manual
Page 29

Page 27
H.I.S. Troubleshooting Manual
disfigured when It is
pushed into cylinder.
Replace stop sleeve and
reassemble unit. Caution:
Be sure stop ring is in
place.
CHAPTER 11:
Hose Trouble Shooting:
Problem
Cause
Action
Hose leaks at fittings
Loose fitting
Tighten fitting. Check
fittings for leakage before
operation.
Damaged fitting or nipple
Damaged threads or
damaged male and female
seats between fittings and
nipples can cause
leakage. Remove and
replace any damaged
parts. Note: a leak proof
system must be
maintained for proper
performance of
equipment.
Crimped hose
If hose has been sharply
bent, the plastic liner can
be ruptured or separated
causing restriction or
blockage of flow. Remove
and replace hose.
Resin hose plugged
Hardened or gelled resin
System is sealed and
filtered. If resin gels or
hardens in hose, gun has
not been properly flushed
and/or needles are not
fully closing on seat. See:
Gun Trouble Shooting,
Chapter 8 to correct this.
Check filter to determine if
screen is in place.
Maintain cleanliness of
screen at all times.