Optional Remote Reset:
Using the items listed below:
1 @ 09125 Bulk head fitting
1 @ 9807-2-1
Pressure Switch
1 @ 9807-1-1 Operator
1 @ 09068 Bracket
1 @ 08801 Fitting
1’@ 08810 1/8 Tubing (plus length to push button)
1 @ 08802
Fitting
1 @ 07223
Fitting
3’@ 08247-BC Wire
1 @ 09169
Push Button
Mount the switch (9807-2-1) in the desired location in the control box and connect the
operator (9807-1-1) to the switch (9807-2-1). Using wire (08247-BC), connect the
switch to terminals #7 and #10 on the back of the Resin meter. Mount the push button
(09169) at the remote location and connect with the tubing (08810), one end of the
tubing to the air supply and the other end to the operator (9807-1-1) on the switch
(9807-2-1).
When you push the button an air signal is sent to the operator on the switch and the
circuit between terminals #7 and #10 is closed causing the resin meter to reset.