weak
2.NRV2 blocked or
broken
Check NRV2 internal seat and
spring
3.Mixer partially blocked Check mixer and renew if
necessary
Catalyst pump
top seal
leakage
beyond top of
pump
1. Worn top seal
Renew seal
2. Catalyst ratio pin
incorrectly set causing
pump shaft distorted
Renew seal and, if the pump shaft
is bent renew and correctly
observe instructions on ratio
adjustment
Resin pump top
seal leaking
beyond pump
lube zone
1. worn top seal
Renew seal
2. Top seal worn quickly
due to non lube renewal
Observe pump lube renewal
3.resin pump left for
extended times in UP
position causing shaft to
become dry
Observe service notes on pump
parking position
4.Filled resin use
A shorter service life will be
expected if highly filled resin is
used. Service life depends on filler
type and filler micron size. Use only
coated fillers with 5 micron filler
particle size