FLOW RATE GPH
25
50
75
100
125
1.5
3.0
4.5
6.0
7.5
PRESSURE PSI
COMP PUMP
®
SERIES 110 FLOW VS. PRESSURE @12.5VDC
(FLOW INCREASES AS PRESSURE DECREASES)
FLOW RATE GPH
30
60
90
120
150
3
6
9
12
15
PRESSURE PSI
COMP PUMP
®
SERIES 140 FLOW VS. PRESSURE @12.5VDC
(FLOW INCREASES AS PRESSURE DECREASES)
1 JAM NUT
2 BYPASS PLUG
3 BYPASS SPRING
4 SCREW, FUEL CHAMBER (2)
5 BYPASS PLUNGER
6 PAD, BYPASS PLUNGER
7 SCREEN, FLAME ARRESTER
8 FUEL CHAMBER
9 GASKET, FUEL CHAMBER
10 PORT PLATE
11 GEROTOR
12 O-RING
13 GEROTOR HOUSING
14 MOTOR
MALLORY IS A DIVISION OF THE MR. GASKET PERFORMANCE GROUP
550 MALLORY WAY, CARSON CITY, NEVADA 89701
(775) 882-6600
FAX (775) 887-4326
www.mrgasket.com
FORM #1022
REV. F (8/00)
MADE IN USA
PRINTED IN USA
4
FIGURE 4
TO ACCESSORIES
IGNITION SWITCH
FROM
VEHICLE
BATTERY
TO COIL (+)
FUSE (7.5 AMP)
FUEL
PUMP
GROUND
12
11
2
3
7
1
4
5
6
8
9
10
13
14
FIGURE 5
BLACK
RED