2 connector electrical characteristics – Avenview FO-DVI-XX-MM User Manual

Page 14

Advertising
background image

www.avenview.com

14

2.7.2 Connector Electrical Characteristics

Item

Test Condition

Requirements

Contact Resistance

ANSI/EIA-364-23

20mΩ, maximum, initial per
contact mated pair
10mΩ, maximum change from
original per contact mated pair

Shell Resistance

ANSI/EIA-364-06A-83
Contact resistance measured from
receptacle shell leg to plug cable
braid. Test current = 100mA; Test
Voltage = 5V DC open circuit
maximum

50mΩ, maximum initial
50mΩ, maximum change from
original

Dielectric Withstanding Voltage

ANSI/EIA-364-20
Test voltage 500V DC



V

Method C, unmated and
un-mounted Barometric pressure
of 15 psi

No Flash-over, No Spark-over, No
Excess Leakage, No Breakdown

Insulation Resistance

ANSI/EIA-364-21
Test voltage 500V DC



V

Method C, unmated and
un-mounted

1GΩ minimum between adjacent
contacts and contacts and shell

Contact Current Rating

ANSI/EIA-364-70, TP-70
55°C, maximum ambient
85°C, maximum temperature
change

1.5A minimum

Applied Voltage Rating

40V AC(ms) continuous maximum,
on any signal pin with respect to
the shield

Electrostatic Discharge

IEC 801-2
Test un-mounted from 1kV to 8kV
in 1kV steps using 8mm ball probe

No evidence of discharge to
contacts. Discharge to the shell is
acceptable.

Advertising