Discontinued – Max Machinery 294_269 High Resolution, Linearized Frequency Transmitters User Manual

Page 5

Advertising
background image

5

an ISO 9001:2008 certified company

Installation - Model 269

Model 269 - Mechanical Installation

Transmitters are installed on the meter at the factory. If a transmitter needs to be replaced in the
field, use the following procedure:

1. Disconnect wiring and remove the two socket cap screws to remove old transmitter.
2. Position alignment key on new transmitter with corresponding notch on the flow meter and drop
into place.
3. Tighten both socket cap screws until snug. Ensure that the transmitter is not crooked, then turn
screws a 1/4 turn. Do not over tighten.

Electrical Connection

This model is wired at the factory. All that is required is to connect the transmitter’s mating cable
into the remainder of the system as follows:

Blue: Case Ground
Black: Common
Brown: Power (+5-26 Vdc)
White: Output Signal

Programming the Transmitter

Contact the factory regarding P/N 294-100-050, user interface software.