Applications

■

Public Buildings

■

Theaters

■

Schools

■

Parking Garages

■

Housing Complexes

In the event of an AC power failure, FirstLine

®

924

automatically supports the connected lighting loads on
battery power and will continue to provide power without
any interruption for a full 90 minutes. When the utility power
returns to normal, FirstLine

®

924 will automatically recharge

the batteries to be ready for the next power disturbance.

Technical Specifi cations

Three-Phase Central Inverter for
Emergency Lighting Applications

General

■

On-line double-conversion topology

■

True sine wave output

■

Continuous, no-break operation

■

Three-phase system will support single

or three-phase loads

■

LCD front panel monitoring and control

■

Automatic system bypass

Input

■

Input Voltage Rating: 208Y/120 and

480Y/277 standard, Delta optional
with

transformer

■

Input Voltage Range: +/-10% system

start-up;

+10% /-15% operation

(166-250Vac,

384-576Vac)

■

Input frequency: 60Hz +/-5%

■

Full load walk-in from 25% to 100% of

rated load in <5 seconds

■

Surge Withstand: Meets IEEE C62.41

Output

■

IGBT: true sine wave PWM inverter

■

Inverter output distortion: <5% THD

(100%

non-linear)

■

Inverter output distortion: <2% THD

(linear

loads)

■

Voltage regulation: +/-1% of nominal

at full load

■

Frequency: 60 Hz

Battery

■

Designed for easy maintenance

■

Standard backup time of 90 minutes at

full

load

■

Valve-Regulated Lead-Acid (VRLA) battery

■

10 year design life at 77°F (25°C)

■

Quick recharging times

Housing

■

Freestanding, NEMA 1 steel enclosure

■

Front and top service access

■

Bottom access for conduit entries

■

Various battery cabinet confi gurations

Environmental

■

Agency Compliance: UL924, FCC and

CSPR22, Class A

■

Operating temperature range 18°F (-8°C)

to 104°F (40°C)

■

Acoustical Noise: 65 db at 3 feet

■

Relative Humidity: 0-95% non-condensing

■

Meets NFPA 101 Life Safety, and

NEC

codes

■

Seismic Zone 4 certifi ed

Monitoring/Communications

■

Front Panel LCD Display

●

4 x 16 character display

●

System status and alarms

■

Communications Port

●

RS-232

●

Dry Contact (AS/400)

●

Remote monitoring

●

SNMP available option

In addition to meeting

life safety requirements,

the FirstLine

®

924 can

also increase the life

expectancy of the

protected lighting system

and reduce long-term

cost of ownership.

Your tailored power solutions provider