MaxPower Corp Relay Interface Card User Manual

Page 2

Advertising
background image

Invensys Powerware
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.356.5794
or 919.872.3020
Fax: 1.800.753.9433
www.powerware.com

Europe
Finland: 358 94 52 661
France: 33 1 6012 7400
Germany: 49 721 961790
Italy: 39 02 6600661 2
UK: 44 (0) 1753 608700

Southeast Asia
Singapore: 65 6861 0377

China and North Asia
Hong Kong: 852 2745 6682

Japan
Shinagawa, Tokyo: 81 3 3447 4441

Australia and South Pacific
Sydney, Australia: 61 29878 5000

Canada
Toronto, Ontario: 416.798.0112

Brazil
Sao Paulo, Brazil: 55 11 3845
4369/ 55 11 3704 3632

Mexico
Col. Napoles, Mexico:
525.488.3333

SFT24FXA

Revision 9/02
Reprint 9/02

PW UPS

Line Fail

Low Batt

UPS Alarm/OK

Bypass

PW 5125

X

X

PW 9120

X

X

X

X

PW 9125

X

X

PW 9170+

X

X

X

X

PW 9330

X

X

X

PW 9340

X

X

X

X

UPS to supported contacts matrix

Description of relay interface card pins and relay information

K1: AC Line

AC line OK

1-2

NC

K2: Battery

AC line failure

1-3

NO

Battery normal

4-5

NC

K3: UPS Alarm

Battery low

4-6

NO

UPS alarm

7-8

NC

UPS ON/OK

7-9

NO

K4: Bypass

UPS on bypass

10-12

NC

UPS normal/on inverter

10-11

NO

UPS shutdown**

13-15

Note: UPS alarm/OK and bypass relay information are not available for PW 5125 and PW 9125 UPSs.

Relay interface card contact information

The relay contacts must not be galvanically connected to any mains-connected circuits. Do not use +12VDC

(Pin13) of the relay interface card for any power supply purposes for external devices. Reinforced insulation

to the mains is required for equipment and cables attached to these connections. Relay contacts are rated

for maximum 1A/30VAC or 200mA/60VDC. All relay outputs are galvanically isolated from the other circuits

of the UPS.

BestDock Relay Interface Card shutdown function

Normally-closed (NC)/-open (NO) connection state when the relay interface card is not powered. **The shutdown pin (15) needs minimum of 5 sec-
onds high level signal (connection to +12VDC) to perform the UPS shutdown. Shutdown function is not available for 9125, 9330, and 9340.

Relay # on board

System State

DB-15 pin#

NC/N0

*

JP1 (factory default)

JP2

JP3

PW 9120

UPS normal

Immediate output off,

Immediate output off

---

online when shutdown

pins are opened

On battery

Shutdown as in RS-232

Immediate output off,

Immediate output off

port; Output off after

online when shutdown

120 sec., back online

pins are opened

when power returns

PW 9170+

UPS normal

---

---

Immediate output off

On battery

---

Immediate output off

Immediate output off