Parts and Instruction Manual

Page 5

Changing the Prefilter

The pink impaction filter should be changed, using all of the precautions previously mentioned.
The impaction filter should be changed when any of the following takes place:

1.

Anytime there is an indication of a filter tear during normal operation of the unit. This tear

could be in any of the filters used.

a.

paper dust containment bag

b.

paper bag protector

c.

cloth filter bag

These tears would show up during the tank clean-out procedure, or....

2.

Every other tank clean-out period. To change the impaction filter, do the following before you do Step #3

of the normal clean-out procedure.

a.

Wipe down all of the exposed surfaces on the underside of the removed lid, using the
dampened wiping cloth.

b.

Remove the pre-filter from the high efficiency filter. Be careful so as not to damage or puncture the
H.E.P.A. / U.L.P.A media used in the final filter. Do not attempt to clean the pre-filter in any way;
dispose of by placing it into the tank you are now in the process of cleaning. DO NOT USE ANY
TOOLS TO REMOVE THE PRE-FILTER.

d.

Before proceeding any further in cleaning the tank, first place a newpre-filter (one only)
onto the H.E.P.A. / U.L.P.A filter.

Assembly Instructions for Dry Recovery Models 30/55 gallon

Refer to Main Assembly, Fig. 2
1.

Place 6 mil. plastic bag liner #7 into drum. Drape bag liner over rim of drum.

2.

Place adaptor ring #6 onto drum.

3.

Insert paper filter protector #3 into drum adaptor ring and drape elastic over rim to secure in place.

4.

Insert cloth filter assembly #2 into adaptor ring and center around rim.

5.

Place vacuum motor lid assembly onto adaptor ring. Attach lid latches.

Emptying Procedure After Dry Recovery

1.

Remove the vacuum lid assembly and place on work table upside down.

2.

Remove and inspect cloth filter assembly. If dust has accumulated on the cloth bag, it will require cleaning
by vacuuming. A second cloth filter assembly should be kept on hand for installation into vacuum so that
soiled filter bag can be cleaned and reused.

3.

Remove filter bag protector elastic from around adaptor rim and push bag into drum for disposal.

4.

Inspect prefilter on side of H.E.P.A. / U.L.P.A filter on vacuum motor lid assembly. If prfilter has been soiled,
remove and place it into drum with other debris.

5.

Install clean prefilter onto H.E.P.A. / U.L.P.A filter.

6.

Using a damp towel, wipe inside of adaptor ring as you remove it from drum. Place soiled towels into
drum liner bag.

7.

Gather plastic liner bag while in drum. Seal and tie liner bag before removing from drum. Tilt drum over on
its side and slide bag liner out of drum. Place into a second 6 mil. liner bag with proper markings for

disposal.
8.

Follow assembly procedure above before putting vacuum back into use.

as close to the filled bag as possible in order to avoid trapping excessive air.

9. Gently remove the bag from the tank. Twist the unfilled portion closed and tie it into a knot.

10. CAUTION: Hazardous materials must be disposed of properly. Never throw contaminated debris in your

usual trash receptacle. Place debris in a plastic bag or can marked “HAZARDOUS MATERIALS” and take
to a hazardous waste handler.

11. For proper assembly of new filters, see “Tank/Filter Set-Up Procedure”.