Minuteman C70555-56 705 Series Industrial Air Operated User Manual

Page 2

Advertising
background image

1

MODEL 705 SINGLE VENTURI

MODEL 705 SINGLE VENTURI

MODEL 705 SINGLE VENTURI

MODEL 705 SINGLE VENTURI

MODEL 705 SINGLE VENTURI

AIR OPERA

AIR OPERA

AIR OPERA

AIR OPERA

AIR OPERATED WET/DR

TED WET/DR

TED WET/DR

TED WET/DR

TED WET/DRY

Y

Y

Y

Y V

V

V

V

VACUUM

ACUUM

ACUUM

ACUUM

ACUUM

OPERA

OPERA

OPERA

OPERA

OPERATING INSTRUCTIONS

TING INSTRUCTIONS

TING INSTRUCTIONS

TING INSTRUCTIONS

TING INSTRUCTIONS

INSPECTION

INSPECTION

INSPECTION

INSPECTION

INSPECTION
Carefully unpack and inspect your machine for shipping damage. Each unit is tested and thoroughly
inspected before shipment, therefore, any damage is the responsibility of the delivering carrier who
should be notified. Read all instructions carefully before operating.

SPECIAL

SPECIAL

SPECIAL

SPECIAL

SPECIAL W

W

W

W

WARNING

ARNING

ARNING

ARNING

ARNING

Air operated equipment can generate static electricity during use. Static dissipating arcing can be
generated and occur if equipment and accessories are not grounded. Risk of explosion is possible
if operated near explosive materials or vapors. Do not operate this equipment near flammable
materials such as solvents, thinners, fuels, grain dust, etc.

AIR PRESSURE

AIR PRESSURE

AIR PRESSURE

AIR PRESSURE

AIR PRESSURE AND C.F

AND C.F

AND C.F

AND C.F

AND C.F.M. VOLUME REQUIRED

.M. VOLUME REQUIRED

.M. VOLUME REQUIRED

.M. VOLUME REQUIRED

.M. VOLUME REQUIRED

For maximum performance, operate with requirements listed below:

Model

Air Supply Line

Maximum Pressure

C.F.M.

705 Single Venturi

1/2"

100

46

Air pressure control valve can be regulated to operate with lower pressure and C.F.M. when maximum
is not required. OPTIONAL: Air pressure regulator can be attached at air valve for positive air pressure
and C.F.M. control.

ASSEMBL

ASSEMBL

ASSEMBL

ASSEMBL

ASSEMBLY

Y

Y

Y

Y PROCEDURE FOR MODEL

PROCEDURE FOR MODEL

PROCEDURE FOR MODEL

PROCEDURE FOR MODEL

PROCEDURE FOR MODEL 705 WET/DR

705 WET/DR

705 WET/DR

705 WET/DR

705 WET/DRY

Y

Y

Y

Y V

V

V

V

VACUUM

ACUUM

ACUUM

ACUUM

ACUUM

1. For wet recovery, attach float assembly #515003, page 4, to underside of vacuum lid with #710359

screw and washer #711543 provided.

2. For dry recovery, attach filter bag assembly #805047, page 5, to underside of vacuum lid. Float

assembly already attached does not have to be removed. To attach filter, refer to page 8 for
assembly.

Always remove the filter bag assembly when vacuum is used for wet recovery.

Advertising