Mcs 352 features and functions – MotorVac CarbonClean Dual System MCS 352 User Manual

Page 8

Advertising
background image

MCS 352 Features and Functions

Descriptions of the gauges, control switches, and status indicators making up the control
panel are listed below. Please become familiar with these features and functions before using
the unit.

Adjust Time Knob

Sets or re-sets the system run time in one-minute increments, from 1
to 60 minutes.

Service Selector

Switch

Selects fuel type: Diesel or Gasoline

Start/Run Switch
(Momentary)

Starts the cleaning cycle.

Run Cycle Light

(green)

Illuminates when the run cycle is under way.

On / Off Switch

Shuts off power to the unit.

On / Off Light (orange)

Illuminates when switch is on.

Fuel Pressure Gauge

Displays output pressure of the unit’s output hose.

Pressure Adjust
Regulator

Used to adjust the gasoline (petrol) system pressure during the
cleaning process on single line fuel systems. Turn clockwise to
close (increase the pressure), counterclockwise to open (decrease the
pressure). Normally closed clockwise for services on two line
systems. (Vehicle controls pressure on two line systems.)

Warning Alarm

Sounds until pump builds pressure, or when the run cycle is
complete or when a pressure loss occurs.

Output Hose (red)

Connects to the input side of the vehicle's engine fuel system.

Return Hose (black)

Connects to the return side of the vehicle's engine fuel system.

Fuel Filter

Filters out contaminants that become removed during the cleaning
process. See

Appendix

for replacement information

Battery Cables

Positive (red) and negative (black) battery connections
(12 VOLTS DC)

Circuit Breaker

15 Ampere circuit breaker for pump

Fuel Tanks (2)

Holds up to 2 liters (70oz.) per tank

Advertising