Troubleshooting – Diamond Products CB240 User Manual

Page 30

Advertising
background image


TROUBLESHOOTING


PROBLEM POSSIBLE

SOLUTIONS


Gas engine will not start.

1) Pull out emergency stop button.
2) Open gas line valve below gas tank.
3) Dead battery?
4) Low engine oil?


Electric motor will not start.

1) Pull out stop button on starter box.
2) Press reset button on starter box.
3) Confirm proper voltage.


Low oil flow.

Check gas engine RPM at tachometer
on front panel. Adjust governor to
3550 RPM if required. See engine
manual.


System builds high pressure with flow
control valve set to zero.

Contamination may have plugged an
orifice in the CF port of the flow valve.
Detach the valve from the front panel
and remove the fitting from the CF
port. A .015” orifice should be visible
at the bottom of the port. Push a fine
wire through the orifice and re-install.

Running with no pressure. Electric
units only.

The motor may be running backwards,
should be counter clockwise. Reverse
any 2 of the 3 power lines coming into
the starter box.




Keep this manual and the engine manual readily available at all times for reference.








The engine exhaust from this product

contains chemicals known to the State of

California to cause cancer, birth defects or

other reproductive harm.

Corporate Office

333 Prospect St., Elyria, Ohio 44035

(216) 323-4616 • Fax: (216) 323-8689

Customer Service: 1-800-321-5336

Customer Service Fax: 1-800-634-4035

30

Advertising
This manual is related to the following products: