Troubleshooting – Diamond Products CB15E-XL User Manual

Page 33

Advertising
background image



TROUBLESHOOTING


PROBLEM POSSIBLE

SOLUTIONS


Electric motor will not start.

1) Pull out stop button on starter box.
2) Confirm proper voltage.


Running with no pressure.

The motor may be running backwards,
should be counter clockwise. Reverse any
two of the 3 power wires coming into the
starter box.


System builds high pressure with flow control
valve set to zero.

Contamination may have plugged an orifice
in the CF port of the flow valve. Detach the
valve from the front panel and remove the
fitting from the CF port. A .015” orifice should
be visible at the bottom of the port. Push a
fine wire through the orifice and re-install.









Keep this manual and the engine manual readily available at all times for reference.








The engine exhaust from this product

contains chemicals known to the State of

California to cause cancer, birth defects or

other reproductive harm.

Corporate Office

333 Prospect St., Elyria, Ohio 44035

(216) 323-4616 • Fax: (216) 323-8689

Customer Service: 1-800-321-5336

Customer Service Fax: 1-800-634-4035

33