OPERATING DRIVEN
EQUIPMENT
 
The operator must know the hydraulic 
requirements and limitations of the driven 
equipment and the appropriate 
adjustments must be made on the controls. 
The introduction of other control devices 
may cause system heating or may render 
the system inoperative. 
 
IMPORTANT: This power unit is 
equipped with a positive displacement 
gear pump. All tools must be equipped 
with a control valve that allows flow 
directly to return ports when not in use. 
Blocking oil flow or abruptly 
disconnecting the tool can send flow 
over relief and potentially overheat the 
system. 
 
Instructions supplied with the driven 
equipment must be followed to ensure 
correct connection and operation of each 
individual piece of equipment. Equipment 
supplied by Diamond Products will be 
capable of being connected correctly and 
will be compatible with this power unit, 
providing neither has been modified from 
original factory configuration. With 
equipment of other manufacturers, it will be 
necessary to determine the following: 
 Correct direction of flow through the 
equipment.
 Correct pressure and flow required by
the equipment.
 Compatibility of any valves or circuitry
and quick disconnects. Some hand-
held equipment uses a trigger control, 
which is operated frequently. These 
valves must be of the open center type 
for correct operation. 
 
IMPORTANT: The quick disconnects 
must be clean when connecting hoses 
and devices. Failure to thoroughly 
clean may result in contamination and 
premature failure of system or tool 
components. 
 
 
 
MAINTENANCE
INSTRUCTIONS
 
 
 Oil Filter: change the filter when 
indicated by the gage at the filter. 
 
 Oil Change: establishing an oil analysis
program is the preferred method of 
determining oil condition and when to 
change it. If the oil is kept clean, dry, 
and operated at moderate 
temperatures, it can last for several 
years. With no analysis program an oil 
change every 200 hours is 
recommended. See the section 
Hydraulic Fluid for specifications. A ½” 
pipe thread oil drain port is at the 
bottom of the hydraulic tank. 
 
 Inspect hoses, couplings, and fittings
daily for leaks, tighten as required. 
Clean quick disconnects frequently. 
Replace any leaking or defective 
components immediately. 
 
 Check hydraulic oil level daily. Fill tank
to upper end of sight tube with unit off. 
 
 Grease the wheel bearings annually. 
 
 
 
 
 
 
 
 
 
40