Chapter 5

TROUBLESHOOTING

1. If your saw does not operate properly, the following table may be used as a guide in

diagnosing and eliminating the problem. If you cannot fix it using this table, call our

service representative.

2. Before calling, be sure you can describe the problem clearly so our representative can

help you. Have this manual at hand.

TROUBLE CAUSE REMEDY

Blade drive pressure

fluctuates.

Speed of motor is too

low.

Power unit is defective.

Change to a smaller

motor or increase

GPM.

Check power unit.

Blade does not rotate

when trigger is

depressed.

Blade is jammed in

cut.

Blade shaft key is

sheared or missing

Power unit is defective.

Remove blade from cut

and try again.

Replace blade shaft

key

Check power unit.

Blade continues to

rotate after trigger is

released

Check valve installed

in wrong direction

Faulty check valve

Re-install check valve

in correct direction

Replace check Valve

Saw motor leaks.

Motor seals are

defective.

Replace motor or

motor seal.

Coupling leaks.

Coupling is defective.

Replace coupling or

coupling seal.

No water at blade.

Water valve is shut.

Water hose not

connected properly.

Low water pressure.

Check water supply.

Check hose

connections.

Check water pressure

(min. 15 psi)

Poor cutting

performance.

Defective saw motor.

Blade is glazed.

Defective power unit.

Replace saw motor.

Dress blade.

Check power unit.